Regenerative Blower Troubleshooting Guide Title
Regenerative Blower
Troubleshooting Chart
Symptom
Potential Cause
Possible Solution
Blower does not produce sufficient pressure/vacuum







Blower is not turned on Turn on blower
Wrong direction of rotation Check and change rotation if required
Vacuum or Pressure gauge is faulty Replace gauge
Blower is not operating at required RPM Check and replace motor if required
Blower has wrong sized impeller Check impeller and replace if required
Pressure or vacuum is lost due to obstruction located between blower and gauge Check for flow restrictions and clean strainers or piping if required
Blower is leaking Fittings are leaking on or around blower Tighten fittings
Blower flow rate is too low Back pressure is too high for blower Reduce back pressure.
Blower may not be sized correctly for process Replace blower
Blower impeller is too small Change blower impeller but watch power consumption on motor
Flow control valve is closed Open flow control valve
May have blocked line or filter Replace filter and clean line